Gas chromatography when is it used




















The Chromatogram will point out the retention times and the mass spectrometer will use the peaks to determine what kind of molecules are exist in the mixture. A simple quadrupole ion-trap consists of a hollow ring electrode with two grounded end-cap electrodes as seen in figure. Ions are allowed into the cavity through a grid in the upper end cap.

Ions that are too heavy or too light are destabilized and their charge is neutralized upon collision with the ring electrode wall. Emitted ions then strike an electron multiplier which converts the detected ions into an electrical signal. This electrical signal is then picked up by the computer through various programs. They are rugged, easy to use and can analyze the sample almost as quickly as it is eluted. The disadvantages of mass spectrometry detectors are the tendency for samples to thermally degrade before detection and the end result of obliterating all the sample by fragmentation.

Flame ionization detectors FID are the most generally applicable and most widely used detectors. In a FID, the sample is directed at an air-hydrogen flame after exiting the column. At the high temperature of the air-hydrogen flame, the sample undergoes pyrolysis, or chemical decomposition through intense heating.

Pyrolized hydrocarbons release ions and electrons that carry current. A high-impedance picoammeter measures this current to monitor the sample's elution. It is advantageous to use FID because the detector is unaffected by flow rate, noncombustible gases and water. These properties allow FID high sensitivity and low noise. The unit is both reliable and relatively easy to use.

However, this technique does require flammable gas and also destroys the sample. Thermal conductivity detectors TCD were one the earliest detectors developed for use with gas chromatography. The TCD works by measuring the change in carrier gas thermal conductivity caused by the presence of the sample, which has a different thermal conductivity from that of the carrier gas.

Their design is relatively simple, and consists of an electrically heated source that is maintained at constant power. The temperature of the source depends upon the thermal conductivities of the surrounding gases. The source is usually a thin wire made of platinum, gold or. The resistance within the wire depends upon temperature, which is dependent upon the thermal conductivity of the gas. TCDs usually employ two detectors, one of which is used as the reference for the carrier gas and the other which monitors the thermal conductivity of the carrier gas and sample mixture.

Carrier gases such as helium and hydrogen has very high thermal conductivities so the addition of even a small amount of sample is readily detected. The advantages of TCDs are the ease and simplicity of use, the devices' broad application to inorganic and organic compounds, and the ability of the analyte to be collected after separation and detection. The greatest drawback of the TCD is the low sensitivity of the instrument in relation to other detection methods, in addition to flow rate and concentration dependency.

Figure 13 represents a standard chromatogram produced by a TCD detector. In a standard chromatogram regardless of the type detector, the x-axis is the time and the y-axis is the abundance or the absorbance.

From these chromatograms, retention times and the peak heights are determined and used to further investigate the chemical properties or the abundance of the samples.

Electron-capture detectors ECD are highly selective detectors commonly used for detecting environmental samples as the device selectively detects organic compounds with moieties such as halogens, peroxides, quinones and nitro groups and gives little to no response for all other compounds.

Therefore, this method is best suited in applications where traces quantities of chemicals such as pesticides are to be detected and other chromatographic methods are unfeasible. The simplest form of ECD involves gaseous electrons from a radioactive? As the analyte leaves the GC column, it is passed over this?

The electrons from the? In the absence of organic compounds, a constant standing current is maintained between two electrodes. With the addition of organic compounds with electronegative functional groups, the current decreases significantly as the functional groups capture the electrons.

The advantages of ECDs are the high selectivity and sensitivity towards certain organic species with electronegative functional groups. However, the detector has a limited signal range and is potentially dangerous owing to its radioactivity. In addition, the signal-to-noise ratio is limited by radioactive decay and the presence of O2 within the detector. Atomic emission detectors AED , one of the newest addition to the gas chromatographer's arsenal, are element-selective detectors that utilize plasma, which is a partially ionized gas, to atomize all of the elements of a sample and excite their characteristic atomic emission spectra.

AED is an extremely powerful alternative that has a wider applicability due to its based on the detection of atomic emissions. MIP is the most commonly employed form and is used with a positionable diode array to simultaneously monitor the atomic emission spectra of several elements.

The components of the Atomic emission detectors include 1 an interface for the incoming capillary GC column to induce plasma chamber,2 a microwave chamber, 3 a cooling system, 4 a diffration grating that associated optics, and 5 a position adjustable photodiode array interfaced to a computer.

Chemiluminescence spectroscopy CS is a process in which both qualitative and quantitative properties can be be determined using the optical emission from excited chemical species. It is very similar to AES, but the difference is that it utilizes the light emitted from the energized molecules rather than just excited molecules.

Moreover, chemiluminescence can occur in either the solution or gas phase whereas AES is designed for gaseous phases. The light source for chemiluminescence comes from the reactions of the chemicals such that it produces light energy as a product. This light band is used instead of a separate source of light such as a light beam. Like other methods, CS also has its limitations and the major limitation to the detection limits of CS concerns with the use of a photomultiplier tube PMT.

A PMT requires a dark current in it to detect the light emitted from the analyte. Another different kind of detector for GC is the photoionization detector which utilizes the properties of chemiluminescence spectroscopy.

Photoionization detector PID is a portable vapor and gas detector that has selective determination of aromatic hydrocarbons, organo-heteroatom, inorganice species and other organic compounds. PID comprise of an ultrviolet lamp to emit photons that are absorbed by the compounds in an ionization chamber exiting from a GC column. Small fraction of the analyte molecules are actually ionized, nondestructive, allowing confirmation analytical results through other detectors.

In addition, PIDs are available in portable hand-held models and in a number of lamp configurations. Results are almost immediate. PID is used commonly to detect VOCs in soil, sediment, air and water, which is often used to detect contaminants in ambient air and soil. The disavantage of PID is unable to detect certain hydrocarbon that has low molecular weight, such as methane and ethane. Gas chromatography is a physical separation method in where volatile mixtures are separated.

It can be used in many different fields such as pharmaceuticals, cosmetics and even environmental toxins. Since the samples have to be volatile, human breathe, blood, saliva and other secretions containing large amounts of organic volatiles can be easily analyzed using GC.

Knowing the amount of which compound is in a given sample gives a huge advantage in studying the effects of human health and of the environment as well.

Air samples can be analyzed using GC. Most of the time, air quality control units use GC coupled with FID in order to determine the components of a given air sample. Although other detectors are useful as well, FID is the most appropriate because of its sensitivity and resolution and also because it can detect very small molecules as well. This method be applied to many pharmaceutical applications such as identifying the amount of chemicals in drugs.

Moreover, cosmetic manufacturers also use this method to effectively measure how much of each chemical is used for their products. Some application, HETP concepts is used in industrial practice to convert number of theoretical plates to packing height. Introduction In early s, Gas chromatography GC was discovered by Mikhail Semenovich Tsvett as a separation technique to separate compounds. Instrumentation Sample Injection A sample port is necessary for introducing the sample at the head of the column.

Figure 1: A cross-sectional view of a microflash vaporizer direct injector. Carrier Gas The carrier gas plays an important role, and varies in the GC used. Figure 3. Gas Recommendations for Packed Columns. Column Oven The thermostatted oven serves to control the temperature of the column within a few tenths of a degree to conduct precise work.

The latter two are proportional to the concentration, however it is the area that is used for quantitation as it is less affected by band broadening. The measurements can be used to calculate the extent of band broadening, the spread of the analyte molecules on the column. Narrower, sharper peaks give better sensitivity signal to noise ratio and better resolution peak separation.

The peaks shown are Gaussian, however peak tailing the right side of the peak is wider indicates activity or a dead volume in the system, whereas a peak fronting the left side of the peak is wider indicates the column is overloaded.

Accurate measurements are affected by the number of data points across a peak, with an ideal number being Too many reduces the signal to noise, reducing sensitivity. For GC-MS data, each data point is a mass spectrum, the third dimension of data. Compared to some other separation techniques, GC has a high peak capacity with the ability to separate hundreds of compounds.

Examples may include the analysis of diesel, or where trace analytes need to be detected in complex matrices like environmental, biological or food samples. Spectral resolution, where an MS is hyphenated to a GC, enables analysis to be performed without full chromatographic resolution, however the coeluting peaks must have different spectra for this to be fully successful.

Only a few cuts can be transferred through the run, therefore it can only be used where there are a few problem separations. Figure 3: GC x GC contour plot of diesel showing the different chemical classes separated. For complex samples where there are frequent coelutions, comprehensive two-dimensional chromatography GC x GC is used. Two columns, containing different stationary phases and therefore different separation mechanisms, are set-up in series.

A modulator is used between the two columns to take a cut from the first column and reinject in a narrow sample band onto the second column. Thermal modulators achieve this using temperature to trap and then release the molecules, flow modulators collect the effluent, compress and flush the molecules onto the second column. Cuts are taken throughout the run, usually every 1 to 10 seconds.

Separation on the second column should be achieved before the next cut is introduced. This fast separation is achieved by using a short, narrow second column, usually m of 0.

GC is a widely used technique across most industries. It is used for routine analysis through to research, analysing a few to many hundreds or thousands with GC x GC of compounds in many different matrices, from solids to gases.

It is a robust technique and is easily hyphenated to other techniques including mass spectrometry. Nov 01 Oct 26 Jun 22 Nov 24 May 04 Nov 13 May 10 Feb 19 Jan 15 Oct 25 Aug 24 Gas chromatography is the process whereby the various elements of a compound are separated into their distinct parts for individual analysis.

Retention time is the time which it takes for an element to release the solvent, and the process normally occurs when a liquid stationary element is transformed into a gaseous mobile element. The process has a wide variety of uses, which are discussed in more detail here , but one of its most important and widely-recognised applicatons is in the field of forensic science. The various ways in which gas chromatography is used in forensics are outlined below.

Since gas chromatography is useful in identifying the individual elements and molecules present in a compound, it has been applied in forensic pathology to determine which fluids and compounds are present inside a human body after death. This is vital in determining whether or the person was intoxicated either from alcohol or drug abuse at the time of death, or indeed whether there is any poison or other harmful substance present in their body.

Of course, this is imperative knowledge to determining cause of death and possible motive and culprit in the case of foul play.